Contralateral Negative Bold Responses in the Motor Network during Subthreshold High-Frequency Interleaved Tms-Fmri over the Human Primary Motor Cortex

Journal of Neurology & Neurophysiology

ISSN - 2155-9562

Research Article - (2018) Volume 9, Issue 6

Contralateral Negative Bold Responses in the Motor Network during Subthreshold High-Frequency Interleaved Tms-Fmri over the Human Primary Motor Cortex

Tsuyoshi Shimomura1*, Minoru Fujiki1, Hiroshi Ohba1, Takanori Kochiyma2, Kenji Sugita1, Hiroyuki Matsuta1, Yukari Kawasaki1, Kohei Oonishi1, Hirotaka Fudaba1 and Thoru Kamida1
1Deparment of Neurosurgery, Oita University Faculty of Medicine, Oita, Japan
2Brain Activity Imaging Center, Advanced Telecommunications Research Institute International, Soraku-gun, Japan
*Corresponding Author: Tsuyoshi Shimomura, Deparment of Neurosurgery, Oita University Faculty of Medicine, Oita, 879-5593, Japan, Tel: +81-97-586-5490, Fax: +81-97-586-6324 Email:

Abstract

Objective: Transcranial Magnetic Stimulation (TMS) is a noninvasive technique that stimulates a localized brain region underneath a coil. Recently, the application of repetitive Transcranial Magnetic Stimulation (rTMS) to the primary motor cortex (M1) has been used to promote functional recovery in stroke patients with hemiparesis. High-frequency rTMS (5 Hz or greater) was applied over the affected hemisphere to reactivate hypoactive regions. Because of recent advances in MRI technology and, in particular, the gradient coils, high-frequency whole brain rTMS-fMRI is possible. The use of interleaved rTMS-fMRI during stimulation at a frequency of 5 Hz aids in understanding how the brain is modulated during stimulation.

Method: We measured BOLD signal changes in whole brain during interleaved rTMS-fMRI (5Hz) using 3T MRI. Image processing and statistical analyses were carried out using the Statistical Parametric Mapping (SPM8) software.

Results: Distinct BOLD signal changes extending to the remote motor network during 5 Hz-rTMS over the M1 were successfully demonstrated using interleaved rTMS-fMRI. Negative BOLD responses were observed in the contralateral M1, the dorsal premotor cortex (PMd), and the bilateral supplementary motor cortex (SMA), even though no significant BOLD signal changes were observed in the stimulated M1. The negative BOLD responses gradually became marked during (3 mins 57 sec). Therefore, long-lasting plastic changes may occur within 4 mins. Negative BOLD responses in remote regions away from the directly stimulated M1 suggest that subthreshold high frequency rTMS over the motor cortex induced neuromodulation via neuronal networks.

Conclusion: The remarkable negative BOLD responses in the contralateral M1 induced by high-frequency rTMS may be useful for identifying a treatment strategy involving M1 stimulation.

Keywords: High frequency rTMS; Negative BOLD; fMRI; Motor cortex; SPM; Neuromodulation; Motor network

Introduction

Transcranial Magnetic Stimulation (TMS) can stimulate brain underneath a coil noninvasively [1]. Because of the unique natures, TMS has been widely used to basic neuroscience research and clinical applications. Nevertheless, it is no fully understood that how to TMS influence to both excitatory and inhibitory neuronal circuits. Recently, the application of rTMS of the primary motor cortex (M1) has been reported to promote functional recovery in stroke patients with hemiparesis due to induced neuroplasticity [2]. Functional recovery was obtained when high-frequency rTMS (5 Hz or greater) was applied over the affected hemisphere to activate hypoactive regions [3-5].

rTMS has been considered to modulate the sensorimotor network by either direct M1 stimulation or by an indirect effect through transsynaptic connections. However, the precise mechanism of its facilitative and inhibitory effects on the sensorimotor network remains uncertain [6]. Functional Magnetic Resonance Imaging (fMRI) studies by M1 TMS demonstrated widespread increases and decreases in Blood Oxygen Level-Dependent (BOLD) signals in cortical and subcortical areas [6-9]. These studies have showed the cortico-cortical and corticosubcortical connections that regulate the sensorimotor network with multisynaptic modulation.

The aim of this study was to establish high frequency (greater than 5 Hz) whole brain interleaved TMS-fMRI by taking advantage of recent advances in MRI equipment and, in particular, the gradient coil system.

We also investigated BOLD signal responses during 5 Hz-rTMS. In addition, we describe the effects of subthreshold high-frequency rTMS (which has recently been used in clinics to promote functional recovery in stroke patients) in directly stimulated M1 and areas distantly connected by neuronal networks. rTMS-fMRI during stimulation at a frequency of 5 Hz is important for understanding treatment strategies using TMS. In this study, we selected 5 Hz-rTMS for study because 5 Hz-rTMS is widely used as a high frequency rTMS in clinical studies and is used as the basic frequency in theta burst stimulation.

Materials and Methods

Six healthy 26 to 36 year-old (mean 33.3; SD 4.3 years) male volunteers, judged according to the Edinburgh Handedness Inventory to be right-handed, participated in this study. None of the subjects Six healthy 26 to 36 year-old (mean 33.3; SD 4.3 years) male volunteers, judged according to the Edinburgh Handedness Inventory to be right-handed, participated in this study. None of the subjects

TMS and electromyography (EMS)

TMS and EMS settings were achieved according to the previous reports [9]. The motor hot spot was identified where obtained a maximal motor response in the right First Dorsal Interosseous (FDI) muscle by TMS. A MRI-compatible figure-eight-coil with a 70 mm outer-wing diameter (MR coil, Magstim, Whitland, Wales, UK) was positioned tangential to the scalp of the subjects at the motor hot spot in a 3-Tesla whole-body MRI scanner equipped with a Circular Polarization (CP) head coil (Siemens Magnetom Verio, Erlangen, Germany). The coil was connected to a biphasic stimulator (Rapid2Plus, Magstim, Whitland, Wales, UK) via a 10 m cable. Motor-Evoked Potentials (MEPs) were recorded from the right FDI with silver/silver chloride surface electrodes with a ground electrode on the dorsal surface of the right wrist, using a BrainAmp system (Brain Products GmbH, Germany) [9]. The TMS coil was fixed to the scanner bed with a custom-made coil holder, and wrapped in bubble wrap. Foam pads were used to minimize head motion during scanning. The resting motor threshold (RMT) was defined for each individual as the percentage of stimulator output that elicited MEPs were >50 μV peak-to-peak amplitude in the FDI at rest in more than 5 of 10 successive trials [10]. The active motor threshold, which is the threshold of detection under approximately 5% maximal voluntary muscle contraction, was also defined (data not shown).

Image acquisition

A time course series of 96 volumes was acquired with a T2*- weighted, single-shot, gradient-Echo Planar Imaging (EPI) sequence. Each volume comprised 24 slices, with a 4 mm slice thickness and a 1 mm gap, and encompassed almost the entire cerebral and superior cerebellar cortices. Images were acquired in the axial plane. The Repetition Time (TR) was 2,400 ms, the Echo Time (TE) was 23 ms, and the flip angle was 90°. The Field of View (FOV) was 210 mm, the voxel size was 3×3×4 mm, the slice gap was 1 mm, and the matrix size was 70×70 mm. The total acquisition times were 3 mins 57 sec, including periods for signal equilibration. T1-weighted structural images were acquired with a 3-D magnetization prepared rapid gradient echo (MPRAGE) in the sagittal plane. The TR was 1,900 ms, the TE was 2.53 ms, the Inversion Time (TI) was 900 ms, and the flip angle was 9°. The FOV was 210 mm, the slice thickness was 1 mm, the slice gap was 0.5 mm, the number of slices collected was 176, and a 192×192×256 matrix facilitated localization.

Interleaved TMS-fMRI was accomplished as previously described [3-5]. In a previous report, the minimum waiting period between a TMS pulse and a subsequent EPI acquisition was 69 ms [7]. Each image was acquired for 91 ms in that report. In recent years, MRI technologies have advanced; thus, the TE and duration required for each image acquisition have decreased. Therefore, in this study, functional images were acquired every 100 ms, and TMS pulses were applied immediately after each image acquisition. The stimulation timing was controlled by Presentation software (Neurobehavioral systems, Albany, CA) on a personal computer that was synchronized with the MRI scanner via transistor-transistor logic pulses converted from the default optical signals of the scanner. In a phantom study, the best timing of the TMS pulse was determined based on the TMS recording and imaging artifacts using the BrainAmp system. The chosen stimulation frequencies of 5 Hz (TMS every two image acquisitions) required 60 ms waiting periods between TMS pulses and subsequent image acquisitions; this design allowed for unperturbed MRI acquisition, as confirmed by phantom experiments. The basic experimental protocol followed a block design. A rest-TMS-rest cycle was repeated eight times and each epoch was 9.6 sec. Therefore, the TMS period was 9.6 sec, and the interval of each TMS period was 19.2 sec (Figure 1). “Rest” indicates that the subject was resting quietly with his eyes closed, and “TMS” indicates TMS at 90% of RMT.

neurology-neurophysiology-scans

Figure 1: Ninety-six scans were obtained over a period of 3 min 57 sec, consisting of four epochs of TMS. TMS was applied at 5 Hz (every two image acquisitions) for 19.2 sec. Image acquisition was achieved within 30 ms, and TMS was applied 60 ms before the RF pulse used for the next image acquisition.

Image processing

Image processing and statistical analyses were performed using the Statistical Parametric Mapping (SPM8) software (Wellcome Department of Cognitive Neurology, London, UK). All EPI images were spatially realigned, normalized and smoothed using the Montreal Neurological Institute (MNI) EPI template and an 8-mm full-width, half-maximum Gaussian filter. At the individual subject level, each task was modeled as a boxcar function, which was subsequently convolved with the canonical hemodynamic response function [8,11]. Data were further treated using a high-pass filter with a cutoff of 128 s and Grand mean scaling. T-contrast was calculated by differences in activation between each task and the resting blocks. The subsequent whole-brain, multisubject analysis was performed by a fixed model analysis. The height threshold for the SPM(T) was set at p<0.05 and was corrected for multiple comparisons across the entire brain. The cytoarchitectonic nomenclature of significant brain activity was determined according to the SPM anatomy toolbox [12]. To detect the time-varying modulation of task-related BOLD responses, we used a first-order time modulation model in SPM8. F-contrast was used to test over all the effects of interest (i.e., the task-related changes and their linear increase or decrease over time). The height threshold for the SPM{F} was set at p<0.05 and was corrected for multiple comparisons across the whole brain with inclusion masked by the main effect (T-contrast, p<0.05, uncorrected).

The percent signal changes in hemodynamic signals were estimated in each subject using Automatic Anatomical Labeling (AAL) ROIs with the Marseille region of interest toolbox (http://marsber.souceforge. net/). The percent signal changes of the bilateral precentral cortex (M1), the bilateral supplementary motor cortex (SMA), and the bilateral thalamus (THA) were sampled. The data were divided into first and second half sessions. ROI analyses were carried out in 5 Hz-rTMS-A and 5 Hz-rTMS-B groups.

Results

The phantom study demonstrated the presence of artifacts caused by TMS at the time of image acquisition (Figure 2A). TMS was applied after image acquisition and 60 ms before the RF pulse used for the next image acquisition; no artifact was observed in any image (Figure 2B). When asked immediately after the experiment, none of the subjects reported any side effects from the experimental procedure, with the exception of a mild, painless sensation from the contact of the TMS coil with their head. The EPI images of the subjects’ brains contained no visible dropouts. We performed a quality check on each sequence and found no artifacts in any images acquired using the interleaved TMSfMRI. No muscle twitch in the right FDI muscle was observed during rTMS-fMRI via video monitoring or with EMG monitoring using the BrainAmp system with MRI-compatible filters.

neurology-neurophysiology-dropouts

Figure 2: (A) Visible dropouts caused by TMS were observed in almost every two images when TMS was applied during image acquisition; (B) No artifacts caused by TMS were observed when TMS was applied 60 ms before the RF pulse used for the next image acquisition.

During high frequency rTMS, distinct positive and negative BOLD responses were induced and spread to the distant motor network areas, despite the lack of significant BOLD signal changes in the directly stimulated left M1. Distinct significantly increased BOLD responses were found in the bilateral S2 and auditory regions. In addition, a slight activation was observed in the bilateral thalamus, the bilateral putamen, and the cerebellum. Remarkable extended, decreased BOLD responses were observed in the right M1 (contralateral to the stimulated side), the right dorsal premotor cortex (PMd), the bilateral SMA, the bilateral prefrontal cortices, and the bilateral parieto-occipital cortices (Figure 3, Table 1).

neurology-neurophysiology-analysis

Figure 3: Activation obtained from a group analysis (six subjects, p<0.05, FWE) of responses to subthreshold rTMS at 90% of the Resting Motor Threshold (RMT) onto axial sections of a standard reference brain (Montreal Neurological Institute, MNI). The left hemisphere is shown on the left. Activation, i.e., positive BOLD MRI responses or signal increases, are coded in red-yellow; BOLD signal decreases are coded in blue. Activation obtained from a group analysis of responses to 5-Hz subthreshold rTMS (Height threshold T=4.747157, p<0.05, FEW; Extent threshold k=0).

Active clusters Volume (mm3) MNI Coordinate T-value
(functional anatomy)       x   y   z  
Positive BOLD          
1 L Superior marginal gyrus (OP1/OP4) 37784 -54 -26 16 12.27
2 R Superior marginal gyrus (OP1/OP4) 22648 50 -26 6 10.67
3 L middle temporal gyrus 576 -58 -64 8 6.88
4 R putamen 2144 30 14 8 6.21
5 L insula 344 -34 26 4 5.71
6 R cerebellum (lobule VI) 112 2 -60 -22 5.39
7 L cerebellum (lobule VI) 136 -2 -78 -24 5.22
               
Negative BOLD          
1 R precentral gyrus ( Area 4a) 206592 42 -18 52 -13.31
2 L precentral gyrus ( Area 4p) 2352 -52 -6 28 -8.68
3 L superior frontal gyrus 12680 -22 64 12 -7.75
4 L temporal lobe 808 -46 24 -38 -7.66
5 L middle frontal gyrus 712 -44 54 -12 -7.07
6 R inferior frontal gyrus 1520 50 4 -38 -6.75
7 R hippocampal gyrus 464 24 -4 -32 -6.47
8 L middle frontal gyrus 1408 -26 34 42 -6.18
9 L temporal pole 448 -50 22 -20 -6.14
10 L middle temporal gyrus 792 -54 -46 -10 -5.79
11 R middle frontal gyrus 736 26 20 56 5.54
12 L middle temporal gyrus 120 -56 2 -28 -5.53
13 L cerebellum (lobule VI) 168 -28 -38 -26 -5.29
14 R superior orbital gyrus 240 28 62 -4 -5.25
15 R fusiform gyrus 120 34 -34 -28 -5.1

T=4.747157 {p<0.05 (FEW)}; Extent threshold k=100 voxels.

Table 1: Results from the group-level statistical parametric mapping analysis: BOLD responses during 5-Hz-rTMS.

Time-varying modulations of the BOLD responses to the 5 HzrTMS were observed in the right M1, the left SMA, and the bilateral parieto-occipital cortices using time modulation analysis with the inclusive mask of the negative BOLD responses (Figure 4). By plotting the fitted response, it was observed that this negative BOLD response decreased gradually. Time-varying modulations were not found in the positive BOLD responses to the 5 Hz-rTMS.

neurology-neurophysiology-responses

Figure 4: Activation obtained from a group analysis of responses to 5-Hz subthreshold rTMS using time modulation with an inclusive mask of the negative main effect (Height threshold F=6.645297, p<0.05, FEW; Extent threshold k=0).

The percent signal change in the bilateral M1 observed during the second-half rTMS was significantly lower than that observed during the first-half rTMS (Figure 5). The percent signal change in the bilateral SMA observed during the second-half rTMS was lower than that observed during the first-half rTMS, but this effect was not significant.

neurology-neurophysiology-profiles

Figure 5: Stimulus-response profiles in the directly stimulated left M1 and remote areas during high-frequency rTMS. *p<0.05 (estimated using Student’s t test). The error bars represent the standard error of the mean. M1: primary motor cortex; SMA: supplementary motor cortex; THA: thalamus; L: left; R: right.

Discussion

Recent advances in MRI technology, especially gradient coil systems, has made possible to perform 5-Hz rTMS-fMRI. Images were acquired every 100 msec, and the whole brain was scanned in 2.4 sec. We chose to use 5 Hz-rTMS because 5 Hz is the standard frequency for clinical TMS therapy and is the basic frequency of theta burst stimulation. This rTMS-fMRI protocol will therefore lead to theta-burst rTMS-fMRI.

The present results demonstrated positive BOLD responses in the bilateral S2, the bilateral auditory regions, the bilateral thalamus, and the cerebellum as the result of 5-Hz interleaved subthreshold rTMSfMRI. Similar to the results found in previous reports [3,4], activation of the directly stimulated M1 was not observed. Clear negative BOLD responses were detected in the contralateral M1, the PMd, and the bilateral SMA while using the rTMS-fMRI frequency protocols. The finding of negative BOLD responses in regions that are remote from the directly stimulated M1 but functionally connected to the motor network suggests that neuronal modulations were induced by the subthreshold high-frequency rTMS across the motor cortex. This effect occurred despite the absence of significant BOLD signal responses in the directly stimulated left M1.

It is generally accepted that positive BOLD signal changes demonstrate increased brain activity [13]. In addition to positive BOLD signal changes, many studies have shown negative BOLD responses in areas such as the occipital cortex during various visual tasks [14,15], motor tasks [16,17], electrical stimulation of the median nerve [18], and TMS [6,7]. Previous investigations have provided indirect evidence that regions exhibiting negative BOLD responses are associated with neuronal suppression [14,15,17,19]. Furthermore, a non-human primate study involving simultaneous fMRI and electrophysiological recordings in monkeys reported direct associations between neural suppression and negative BOLD responses [20]. Our imaging data demonstrated that no significant activation of the ipsilateral M1 occurred while using high-frequency subthreshold rTMS. The absence of significant BOLD signal changes in the stimulated M1 has been noted previously and is suggested to be primarily due to the lack of afferent feedback from actual muscle movements induced by the TMS pulses [6,7]. Based on previously recommended safety guidelines [21], suprathreshold TMS was not used in this study.

Electrophysiological data have shown that subthreshold stimulation activates cortical circuitry, even if it fails to elicit the cortico-spinal output necessary for a muscle twitch [22,23]. Conversely, paired pulse experiments in which a small initial stimulus is used to condition the response to a larger test stimulus have clearly shown that subthreshold TMS can affect the excitability of cortical circuits [7,23]. Although Intracortical Inhibition (ICI) is partly regulated by GABA via postsynaptic GABAA-receptor activation [24], Intracortical Facilitation (ICF) is likely a more complex phenomenon because more than one neurotransmitter (i.e., glutamate, dopamine, and GABA) may be involved [25]. Thus, subthreshold pulses induce the trans-synaptic excitation of cortical neurons via interneurons. It is known that an increased distance results in insufficient sensitivity for the detection of subtle BOLD MRI signal changes at the stimulation site. Bestmann et al. speculated that this phenomenon is likely due to the self-canceling of inhibitory and excitatory processes, leading to negligible net synaptic activity with no hemodynamic output, together with the occurrence of altered hemodynamic response characteristics that may not be detected using common response functions [7]. These authors advocated a model in which local hemodynamic changes that are evoked at the site

of stimulation by subthreshold rTMS do not exceed the background physiological “noise” level. In our study, the percent signal change of the left M1 during 5 Hz-rTMS-A revealed a slight increase in activity, followed by a significant decrease that became negative during 5 HzrTMS- B. This activity resulted in a lack of any overall signal change during 5 Hz-rTMS. Furthermore, a recent study demonstrated that 5 Hz-rTMS produces an increase in the Cortical Silent Period (CSP) duration that is not affected by repetitive paired pulse TMS [26]. CSP reflects the activation of postsynaptic GABAB-receptors, presumably on intracortical interneurons [27]. The coexistence of inhibitory and excitatory neuronal intracortical modulation at the directly stimulated site may have led to the observed fluctuating BOLD signals and may have resulted in the absence of significant activity increases in the left M1.

Similar to the findings of previous reports [6,7], we observed markedly negative BOLD responses in the contralateral M1 during high-frequency rTMS. Interhemispheric Inhibition (IHI) is a wellknown phenomenon that was first described by Ferbert et al. [28]. In this phenomenon, a conditioning TMS to M1 reduces the EMG activity produced by a second pulse to the contralateral M1 within an Interstimulus Interval (ISI) of 6-50 ms [29]. This event is likely to occur at the cortical level [28,29] and is mediated through excitatory commissural neurons that have a propagation time of approximately 10-15 ms, exciting local inhibitory interneurons in the contralateral M1 [30]. Subsequent study reported that IHI between homologous M1s at ISI of 10 ms (short latency IHI; SIHI) and of 40 ms (long latency IHI; LIHI) may have different physiological origins [31]. SIHI/LIHI is widely distributed among motor related cortical areas, and suggests that this inhibitory drive may contribute to unimanual and coordinated bimanual movements at different stages of motor control, including the decision making, movement selection and execution [32]. Palmer et al reported that the firing of layer 5 pyramidal neurons in rat somatosensory cortex due to contralateral sensory stimulation was inhibited for hundreds of milliseconds when paired with ipsilateral stimulation. The inhibition acted directly on apical dendrites via layer 1 interneurons but was silent in the absence of pyramidal cell firing, relying on metabotropic inhibition of active dendritic currents recruited during neuronal activity [33]. IHI has also been observed during transcranial electrical cortex stimulation (TES) [29]. When a contralateral conditioning stimulus preceded the test stimulus by 10 ms, the subsequent ipsilateral BOLD signal was significantly reduced. The negative BOLD responses in the contralateral M1 observed during high-frequency subthreshold rTMS were likely caused by IHI, which was mediated via excitatory commissural neurons acting on local inhibitory interneurons in the ipsilateral M1. A near-infrared spectroscopy study demonstrated that TMS using continuous theta bursts over M1 elicited a significant oxy- Hb decrease in the contralateral M1 [34].

Recently, the application of rTMS of the primary motor cortex has been reported to promote functional recovery in stroke patients with hemiparesis owing to induced neuroplasticity [35]. Functional recovery was obtained both when low-frequency rTMS (around 1 Hz) was applied over the disinhibited, unaffected hemisphere to restore defective inhibition [36] and when high-frequency rTMS (5 Hz or more) was applied over the affected hemisphere to activate hypoactive regions [37,38].

Our imaging data also revealed distinctly negative BOLD responses of the bilateral SMA. Conversely, positive as well as slightly negative BOLD responses of the SMA, without emphasis, have been previously reported [6,7]. Negative BOLD responses of the SMA were clear, and these effects are likely to have been associated with the negative BOLD responses observed in the contralateral M1. The SMA is densely interconnected with the M1 through the motor loop, one of the basal ganglia-thalamocortical connections [39]. The negative BOLD responses of the bilateral M1 may lead to the negative BOLD responses of the bilateral SMA through the multisynaptic neuronal network of the motor loop. Our findings demonstrated that gradually decreased BOLD responses to the 5 Hz-rTMS were observed in the right M1 and the left SMA using time modulation analysis with the inclusive mask of the negative BOLD responses. Further, the time course of the percent signal change in each session demonstrated a gradually decreased BOLD response in the bilateral M1. Long-lasting plastic changes can occur within 4 mins during 5 Hz-rTMS-fMRI.

In this study, we observed markedly decreased BOLD responses in the contralateral M1 during high frequency rTMS, despite a lack of significant BOLD signal changes in the stimulated M1. We speculate that neuronal modulation of the decreased activity in the contralateral M1 might have decreased the TCI from the contralateral M1 to the ipsilateral M1, which might in turn have increased the excitability of the ipsilateral M1. However, further studies are needed to test this hypothesis. The robust negative BOLD response in the contralateral M1 that was induced by high-frequency rTMS could provide promising alternative treatment strategies using M1 stimulation.

In conclusion, we successfully demonstrated distinct BOLD signal changes that extended to the remote motor network during 5 Hz-rTMS over the M1 using interleaved rTMS-fMRI. The remarkable negative BOLD responses in the contralateral M1 induced by high-frequency rTMS might have diminished TCI from the contralateral to the stimulated M1.

Acknowledgements

Declaration of interest: The authors declare that no conflicts of interest exist that could be perceived as prejudicing the impartiality of the research reported. Funding: This work was supported by a grant from the Japan Science and Technology Agency and the Ministry of Education, Culture, Sports, Science, and Technology.

References

Citation: Shimomura T, Fujiki M, Ohba H, Kochiyma T, Sugita K, et al. (2018) Contralateral Negative Bold Responses in the Motor Network during Subthreshold High-Frequency Interleaved TMS-fMRI over the Human Primary Motor Cortex. J Neurol Neurophysiol 9: 478.

Copyright: © 2018 Shimomura T, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.